Visible and Fluorescent - a2La

180kB Size 5 Downloads 9 Views

ASTM E94, E1032; ASME Section V Art. 2,. Section VIII, Section IX, B31.1, B31.3, B31.4,. B16.34; API 6A, 1104; MIL-STD 453C;. AWS D1.1, 1.2, 1.5; AAR Spec.
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FUGRO USA LAND, INC. 10831 Train Court Houston, TX 77041 Phillip Zaragoza Phone: 713 937 0029

NONDESTRUCTIVE Valid To: September 30, 2018

Certificate Number: 0023.04

In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory at the location listed above as well as the one (1) satellite laboratory location listed below, to perform the following tests: Tests:

Test Methods:

Radiography Testing1 (X-Ray and Gamma) (Gamma=Ir-192, Co-60 and Se-75) Digital and Film

ASTM E94, E1032; ASME Section V Art. 2, Section VIII, Section IX, B31.1, B31.3, B31.4, B16.34; API 6A, 1104; MIL-STD-453C; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); AAR Spec. M-1002; AWWA D-100, C-206

Penetrant Examination1 Visible and Fluorescent

ASTM E165, E1208, E1209, E1210, E1219, E1220, E1417; ASME Section V Art. 6, Section VIII, B31.1, B31.3, B31.4, B16.34; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104, 6A; AAR Spec. M-1002; MIL-STD-6866

Magnetic Particle Examination 1 Wet, Dry, Visible, Fluorescent, with Yoke & Bench

ASTM E709, E1444; ASME Section V Art. 7, Section VIII, B31.1, B31.3, B31.4, B16.34; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104, 6A; AWWA C-206; MIL-STD-1949

Ultrasonic Contact Method1, Straight and Angle Beam1

ASTM E114, E164; ASME Section V Art. 4 and 5, Section VIII, B31.1, B31.3, B31.4, B16.34; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104, 6A; AAR Spec. M-1002

Visual1

ASME Section V Art. 9, Section VIII, Section IX B31.1, B31.3; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104; AAR Spec. M-1002

(A2LA Cert. No. 0023.04) 01/11/2017

page 1 of 3

Tests:

Test Methods:

Welder Qualifications 1 NDT Methods

ASME Section VIII, Section IX, B31.1, B31.3; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104; AAR Spec. M-1002

Welding Procedure Qualifications 1

ASME Section VIII, Section IX, B31.1, B31.3; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104; AAR Spec. M-1002

This accreditation covers testing/calibration performed at the main laboratory listed above, and the following satellite laboratory listed below.

FUGRO CONSULTANTS INC. 2410 East Pasadena Freeway Pasadena, TX 77506 NONDESTRUCTIVE Tests:

Test Methods:

Radiography Testing 1 (X-Ray and Gamma) (Gamma=Ir-192, Co-60 and Se-75)

ASTM E94, E1032; ASME Section V Art. 2, Section VIII, Section IX, B31.1, B31.3, B31.4, B16.34; API 6A, 1104; MIL-STD-453C; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); AAR Spec. M-1002; AWWA D-100, C-206

Penetrant Examination1 Visible and Fluorescent

ASTM E165, E1208, E1209, E1210, E1219, E1220, E1417; ASME Section V Art. 6, Section VIII, B31.1, B31.3, B31.4, B16.34; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104, 6A; AAR Spec. M-1002; MIL-STD 6866

Magnetic Particle Examination 1 Dry, Visible, Fluorescent, with Yoke

ASTM E709, E1444; ASME Section V Art. 7, Section VIII, B31.1, B31.3, B31.4, B16.34; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104, 6A; AWWA C-206; MIL-STD-1949

Ultrasonic Contact Method1, Straight and Angle Beam1

(A2LA Cert. No. 0023.04) 01/11/2017

ASTM E114, E164; ASME Section V Art. 4 and 5, Section VIII, B31.1, B31.3, B31.4, B16.34; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104, 6A; AAR Spec. M-1002

page 2 of 3

Tests:

Test Methods:

Visual1

ASME Section V Art. 9, Section VIII, Section IX B31.1, B31.3; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104; AAR Spec. M-1002

Welder Qualifications 1 NDT Methods

ASME Section VIII, Section IX, B31.1, B31.3; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104; AAR Spec. M-1002

Welding Procedure Qualifications 1

ASME Section VIII, Section IX, B31.1, B31.3; AWS D1.1 (clause 6, inspection), 1.2 (clause 6, inspection), 1.5 (clause 6, inspection); API 1104; AAR Spec. M-1002

1

These laboratories meet A2LA R104 – General Requirements: Accreditation of Field Testing Laboratories for these tests.

(A2LA Cert. No. 0023.04) 01/11/2017

page 3 of 3

Accredited Laboratory A2LA has accredited

FUGRO USA LAND, INC. Houston, TX for technical competence in the field of

Nondestructive Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009).

Presented this 11th day of January 2017.

_______________________ President and CEO For the Accreditation Council Certificate Number 0023.04 Valid to September 30, 2018

For the tests to which this accreditation applies, please refer to the laboratory’s Nondestructive Scope of Accreditation.

Comments